  Datasheet File OCR Text:
 TFS433R.doc
version 3.1
24.05.2002
VI TELEFILTER
Filter Specification
TFS 433 R
1/5
Measurement condition
Ambient temperature: Input power level: Terminating impedances* for input: for output: Coupling coil: 23 C 0 dBm 560 -1,25 pF 560 -1,25 pF 47 nH
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 433 R is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 433,92 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance of centre frequency fc.
Data
Insertion loss (Reference level) Nominal frequency Centre frequency ae = amin
fN fc
typ. value
3,8 433,95 BW 0,8 32 50 58 61 53 58 0,5 TC ** -0.036 ppm/K + 20 C dB dB dB dB dB dB dB s MHz dB
tolerance/limit
max. 6,5 dB
433,920 MHz
Guaranteed 1,5 dB signal band width Relative attenuation fN 80 kHz fN 460 kHz ... fN fN 660 kHz ... fN fN 1 MHz ... fN fN + 1 MHz ... fN fN + 2 MHz ... fN fN 5 MHz ... fN Group delay ripple fN 70 kHz arel 660 kHz 1 MHz - 13 MHz + 2 MHz + 5 MHz 13 MHz GD
min. max. min. min. min. min. min. min. max.
160 1,5 25 40 50 50 47 50 2
kHz dB dB dB dB dB dB dB s C C
Operating temperature range Storage temperature range Temperature coefficient of frequency Frequency inversion temperature *)
- 40 C ... + 85 - 40 C ... + 85 -
The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
Generated: Checked / approved:
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS433R.doc
version 3.1
24.05.2002
VI TELEFILTER
(All dimensions in mm)
Filter Specification
TFS 433 R
2/5
Construction, pin configuration and 50 - matching network
5.0 SQ -0.1 7 5
+0.15
433 R P19
1 Date code
Pin 1 Pin 2 Pin 3 Pin 4,8 Input Input RF Return External Coil Package Ground Pin 5 Output Pin 6 Output RF Return Pin 7 Ground Date code: M N P ... Year + week 2000 2001 2002
3
50 Ohm Test circuit 1
L1 1 5 L2
C1
SAW
3 2, 4, 6, 7, 8 L3
C2
50 Ohm Test circuit 2
C1
1
5
C2
L1
SAW
3 2, 4, 6, 7, 8 L3
L2
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS433R.doc
version 3.1
24.05.2002
VI TELEFILTER
Stability Characteristics
Filter Specification
TFS 433 R
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer 3000 min 300 mm min 500 mm min 300 mm
Tape (all dimensions in mm) W Po : : 12 4 0,3 0,1
Po
EMBOSSED CARRIER TAPE
Do
P2
Do : E : F : G (min) : P2 : P1 : D1(min) : Ao Bo CT : : :
1,5 + 0,1 1,75 0,1 5,5 0,05 0,75 2 8 1,5 5,3 5,3 9,5 0,05 0,1 0,1 0,1 0,1
CT Bo
E Ao D1 F W
G
P1
COVER TAPE
W2
Reel (all dimensions in mm): A W1 N (min) C : : : : 330 12,4 + 0,2 18,4 50 13 +0,5 -0,2
A C N
W2 (max) :
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS433R.doc
version 3.1
24.05.2002
VI TELEFILTER
Air reflow temperature conditions
Filter Specification
TFS 433 R
4/5
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS433R.doc
version 3.1
24.05.2002
VI TELEFILTER
History
Version 1.0 1.1 1.2 Reason of Changes 3.1 -
Filter Specification
TFS 433 R
5/5
Name Dr. Wall Dr. Wall Dr. Wall
Date 14.03.2002 21.03.2002 22.04.2002
Generate specification according to customer requirements Change pinning according to discussion with customer. Change development specification to preliminary specification. Add termination impedances. Add typical data. Position of coupling coil changed from pin 7 to pin 3 Change starting frequency for 25 dB selection from fN 400 kHz to fN 460 kHz. Change starting frequency for 40 dB selection from fN 600 kHz to fN 660 kHz. Change typical values. Change termination impedances. Change preliminary specification to filter specification.
1.3 3.0
Dr. Wall Dr. Wall
23.04.2002 29.04.2002
Dr. Wall
24.05.2002
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.